An AI Data Center Interview and a Direction I’m Excited to Pursue

Rack Notes · Personal field note

By Brian Fulcher · Interview and technical review: November 19, 2026

Editorial illustration of an engineer holding a notebook in a data center aisle, with amber-lit server racks and teal network cabling.
AI-generated conceptual illustration for Root Access Guy; not a photograph of the interview site.

On November 19, 2026, I interviewed for a role supporting an AI data center. I’m grateful for the conversation. It was humbling, gave me specific things to learn, and left me more interested in where this part of the industry could take my career.

I’ve spent more than 15 years working across enterprise networking, systems engineering, virtualization, security, infrastructure, and senior technical escalations. I’ve also worked with NVIDIA Quadro P4000 and RTX 4090 GPU environments.

When the conversation turned to H200 and B200 hardware, my mind was still on the systems I had supported before. I blanked on the model names.

After years of being someone other engineers turn to for help, that was a useful experience to sit with. It gave me a clear place to focus my learning and a reason to think more seriously about this opportunity.

A direction I’m excited to explore

The opportunity connects with my earlier data center work with Wachovia and Lincoln Financial Group. That experience is part of why returning to data center work appeals to me.

I like understanding how hardware, connectivity, software, and operations depend on one another. When a service fails, those relationships help you work out where to look, what evidence to collect, and who needs to be involved.

AI infrastructure feels like a worthwhile direction to pursue. I would bring years of experience investigating problems across those boundaries, along with a willingness to learn the platforms and operating practices specific to the environment.

What I went back to review

After the interview, I started reviewing the accelerators and the systems around them. These notes describe what I’m learning and how I would structure an investigation.

Workstation GPUs also span a wide range of memory capacities. NVIDIA’s Quadro RTX 8000 has 48 GB of GDDR6, while the RTX PRO 6000 Blackwell Workstation Edition has 96 GB of GDDR7 with ECC. Memory capacity is one part of the comparison; memory technology, interconnects, and platform design matter too.

Sources: NVIDIA Quadro RTX 8000 data sheet · NVIDIA RTX PRO 6000 Blackwell Workstation Edition

H200 and B200 in context

The H200 uses NVIDIA’s Hopper architecture; the B200 belongs to Blackwell. For the SXM GPUs in NVIDIA’s HGX reference configuration, the memory comparison is:

GPUArchitectureMemory per GPU
H200 SXMHopper141 GB HBM3e
B200 SXMBlackwell180 GB HBM3e

Those are specific configurations, not specifications for every product carrying a related name. Identifying the exact platform matters when checking supported drivers, firmware, power limits, and operating procedures.

Sources: NVIDIA HGX H100, H200 and B200 reference architecture · NVIDIA H200 · NVIDIA Blackwell architecture

GPU interconnects and network fabrics

The technologies around the GPUs serve different purposes:

  • NVLink provides high-bandwidth GPU interconnection; NVSwitch switches NVLink traffic. An NVLink domain can extend across a rack-scale system, depending on the architecture.
  • RDMA, or Remote Direct Memory Access, allows data transfer between memory regions with reduced CPU involvement.
  • InfiniBand is a specialized networking architecture commonly used for compute fabrics. RoCE carries RDMA over Ethernet; RoCEv2 uses UDP/IP encapsulation.

That distinction changes the investigation: a reachable management interface does not establish that GPU communication is healthy.

Sources: NVIDIA certified systems configuration guide · NVIDIA RoCE guidance

How I would work through a GPU or fabric problem

A command becomes useful when I understand what it checks and what remains untested. I would use the following sequence, adjusting it to the observed failure and the site’s procedures.

1. Establish the scope

I would compare timestamps, affected jobs, and affected nodes. A group sharing a switch, rack, power feed, or cooling dependency points toward a common cause. If the issue is isolated, I would compare that node with a healthy equivalent and check recent changes.

2. Check GPU visibility and health

nvidia-smi and nvidia-smi -q provide GPU information, including supported health and performance fields. A missing GPU, driver communication failure, thermal slowdown, or relevant error trend gives the investigation a direction. I would correlate that with host and hardware logs before choosing a repair.

If those checks look normal, nvidia-smi topo -m helps compare GPU/NIC connections with the intended design. An unexpected path deserves investigation; a normal topology diagram still does not prove throughput.

Sources: NVIDIA System Management Interface reference

3. Identify the fabric and check the adapter

ibstat and ibv_devinfo help identify adapter and port state. I would inspect the actual Link layer field: a transport label containing “InfiniBand” alone does not establish that the port is using an InfiniBand fabric.

For InfiniBand, a physical link down points back to the cable, port, or adapter. A physical link up with the port not yet Active calls for fabric-initialization and subnet-manager checks. If the port is Active but communication fails, I would examine addressing and partition membership. For RoCE, I would check the corresponding Ethernet interface, IP configuration, VLAN, MTU, and route.

Sources: NVIDIA RDMA link-layer checks · NVIDIA NCCL network troubleshooting

4. Check physical errors and optical evidence

On a supported Ethernet interface, ethtool <interface> checks link settings, ethtool -S <interface> exposes driver statistics, and ethtool -m <interface> reads supported module diagnostics.

Unexpected speed, increasing errors or drops, or optical measurements outside the module’s limits help narrow the fault. Historical nonzero counters need context, so I would compare changes during the incident. If the physical path looks healthy, I would move to congestion, fabric counters, and end-to-end performance.

Sources: NVIDIA physical-link and optical diagnostics

5. Test the remaining hypothesis and validate recovery

I would compare existing RDMA and workload telemetry with a healthy baseline. If an additional bandwidth test were needed, I would coordinate it because it generates real traffic. Healthy fabric evidence would shift attention to storage latency, CPU/data-loading pressure, scheduler state, and application logs.

Once the fault is isolated, I would follow the appropriate recovery procedure and verify workload performance afterward. Reboots, adapter resets, and configuration changes need a reason supported by the evidence.

Sources: NVIDIA NCCL network troubleshooting

Fiber color is a starting clue

Physical troubleshooting also depends on identifying the actual cable. These are common jacket conventions for indoor or patch cabling:

Fiber categoryCommon jacket identification
OM1 multimodeOrange
OM2 multimodeOrange
OM3 multimodeAqua
OM4 multimodeAqua or Erika violet
OM5 multimodeLime green
OS2 single-modeYellow

I would verify the jacket markings, part number, and specifications. Color can vary by manufacturer, region, and custom order; it does not establish the fiber’s suitability for a particular link. Connector-color conventions are a separate matter.

Sources: Corning fiber cabling basics · Fluke multimode fiber identification · Fluke OM5 overview

Connectors and transceiver form factors

LC and MPO describe connector interfaces. MTP is US Conec’s branded MPO implementation. SFP, QSFP, and OSFP describe pluggable module families. A QSFP optical module can use an MPO connector.

Sources: Fluke MPO and MTP explanation

Module form factorCommon Ethernet examples
SFP+ / SFP2810G / 25G
QSFP+ / QSFP2840G / 100G
QSFP56200G
QSFP112400G
QSFP-DD / OSFP400G and higher, depending on module and port

The form factor alone does not tell me the required fiber, connector, wavelength, reach, breakout mode, or FEC settings. I would verify the module and host-port specifications together. A cable that fits is only the beginning of that check.

Sources: Cisco transceiver and breakout guide · Cisco 400G QSFP112 data sheet · NVIDIA physical-link and optical diagnostics

What an RX reading actually tells me

A valid 0 dBm reading means 1 mW of received optical power. It must be compared with that receiver’s specified limits. It does not mean there is no light, and more received power is not automatically better.

A valid reading near −49 dBm would be far below the useful range of typical data center optics. Before concluding that the fiber is faulty, I would check whether the module supports the measurement and whether the value represents a reporting floor or invalid telemetry. An unsupported raw zero is also different from a valid 0 dBm measurement.

Then I would compare corresponding local RX and far-end TX lanes, inspect polarity and the fiber path, and correlate the readings with link state and errors. That evidence guides whether the next step is connector inspection and cleaning, a compatible replacement, or further investigation elsewhere.

Sources: Fluke dB versus dBm · NVIDIA physical-link and optical diagnostics

What years of escalation work have taught me

In senior roles, I’ve taken on issues that had already passed through several rounds of troubleshooting. Those situations demand patience, careful questions, and a willingness to revisit assumptions.

Sometimes the useful clue is a changed dependency, an integration behaving unexpectedly, or a difference between the affected system and a working one. Connecting those observations has helped me make progress in unfamiliar environments.

I’ve also built integrations and automation to reduce repetitive work. Useful automation needs clear inputs, visible outcomes, and a way to recognize when a person needs to intervene.

The same applies to monitoring. An alert should help someone decide what to do. A ticket needs enough context to move an investigation forward. An incident needs an owner, a response process, and communication that keeps people informed. That is the operational thinking behind IT ticket triage with a person in charge.

Restoring service is one part of the job. Understanding the cause, improving documentation, and reducing recurrence make the next investigation easier.

What I want to carry forward

As I get older, the technology landscape keeps becoming more expansive and specialized. I don’t know every platform, and I probably never will.

What I have developed is the ability to connect past knowledge to unfamiliar problems, work through uncertainty, and take ownership of the outcome. Reviewing a reliable source, explaining it in my own words, and applying it to a new example are practical ways to keep building that ability. That is the approach explored in A learning loop that keeps you thinking.

This interview helped clarify both a learning gap and a direction I’m excited to pursue. I’m thankful for that.

The hardware will keep changing. I’ll keep learning, connecting experience to new challenges, and doing the work to make those systems reliable.